1. Flags

A set of flags are used to toggle certain functionality:

Flag Description Default

Duty Cycle

Comply with the ETSI/FCC duty cycle limitations. If flag is set, duty cycle is enforced by the device firmware.

On

Buzzer

Enable/disable acoustic feed back using the integrated buzzer

On

Confirmed uplinks

Confirmed uplinks are used for button press report messages to make sure, it is received by the network

Off

Ambiguous first press

Enforce only one button is interpreted as the first press. If more than one button is activated, it may be that multiple buttons are interpreted as the first press. If this flag is set, no message is sent if that happens. This is recommended to be used with long debounce time.

Off

Slowest join

Set join strategy: If set, join with slowest DR; if not set, start with highest DR and decrease DR over time if join is not successful

On

2. Configuration

These miscellaneous configuration options are used to fine tune the device functionality:

Setting Description Default

Button mode

Bit mask to configure active buttons. Each button can be configured individually. [0 - 16]

16 (ALL)

Status interval

Time of the periodic keep alive message in minutes. [0 - 65536]

1440

Button debounce

The device is activated by the first registered button press. After the button debounce time in milliseconds, a second reading is taken before the message is sent to the network

20 ms